Formats Available: Online, Print
Product Overview

CAN/CSA-C22.2 NO. 60601-2-21-10 (R18)

CSA Group Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers (Adopted IEC 60601-2-21:2009, second edition, 2009-02) | Appareils électromédicaux - Partie 2-21: Exigences particul

Total
As low as $210.00
Select Format Required

More About This Product

Description
CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60601-2-21, Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 60601-2-21 (second edition, 2009-02). It supersedes the previous edition, published in 1998 as CAN/CSA-C22.2 No. 601.2.21, Medical electrical equipment - Part 2: Particular requirements for the safety of infant radiant warmers (adopted CEI/IEC 601-2-21:1994). It is one in a series of Standards issued by CSA under Part II of the Canadian Electrical Code. Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: - devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information see IEC 80601-2-35; - INFANT INCUBATORS; for information see IEC 60601-2-19; - INFANT TRANSPORT INCUBATORS, for information see IEC 60601-2-20; - INFANT PHOTOTHERAPY EQUIPMENT, for information see IEC 60601-2-50. ------------------------------------------------------------------------------------------------------------------------------ Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60601-2-21, Appareils électromédicaux - Partie 2-21 : Exigences particulières pour la sécurité de base et les performances essentielles des incubateurs radiants pour nouveau-nés. Il s'agit de l'adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 60601-2-21 (deuxième édition, 2009-02), qui porte le même titre. Cette norme remplace l'édition précédente publiée en 1998 et intitulée CAN/CSA-C22.2 nº 601.2.21, Appareils électromédicaux - Partie 2 : Règles particulières de sécurité des incubateurs radiants pour nouveau-nés (norme CEI/IEC 601-2-21:1994 adoptée). Cette norme fait partie d'une série de normes publiées par CSA lesquelles constituent le Code canadien de l'électricité, Deuxième partie. Domaine d'application Remplacement: La présente norme internationale s'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des INCUBATEURS RADIANTS POUR NOUVEAU-NES, comme définis dans 201.3.204, également désignés sous le terme APPAREILS EM. Si un article ou un paragraphe est spécifiquement destiné à être applicable uniquement aux APPAREILS EM ou uniquement aux SYSTEMES EM, le titre et le contenu de cet article ou de ce paragraphe l'indiquent. Si tel n'est pas le cas, l'article ou le paragraphe s'applique à la fois aux APPAREILS EM et aux SYSTEMES EM, selon le cas. Les DANGERS inhérents à la fonction physiologique prévue des APPAREILS EM ou des SYSTEMES EM dans le cadre du domaine d'application de la présente norme ne sont pas couverts par des exigences spécifiques contenues dans la présente norme, à l'exception de 7.2.13 et de 8.4.1 de la norme générale. NOTE Voir aussi 4.2 de la norme générale. La présente norme particulière spécifie les exigences de sécurité relatives aux INCUBATEURS RADIANTS POUR NOUVEAU-NES, mais des méthodes alternatives de conformité avec un article spécifique, en démontrant un niveau équivalent de sécurité, ne seront pas jugées comme non conformes, si le FABRICANT a démontré dans son DOSSIER DE GESTION DES RISQUES que le RISQUE présenté par le DANGER s'est révélé avoir un niveau acceptable, lorsqu'il a été évalué par rapport aux avantages du traitement présentés par le dispositif. La présente norme particulière ne s'applique pas: - aux dispositifs délivrant de la chaleur par l'intermédiaire de COUVERTURES, COUSSINS ou MATELAS en usage médical; voir la CEI 80601-2-35 à titre informatif; - aux INCUBATEURS POUR NOUVEAU-NES; voir la CEI 60601-2-19 à titre informatif; - aux INCUBATEURS DE TRANSPORT POUR NOUVEAU-NES; voir la CEI 60601-2-20 à titre informatif; - aux APPAREILS DE PHOTOTHERAPIE POUR NOUVEAU-NES, voir la CEI 60601-2-50 à titre informatif.
CSA Preface This is the second edition of CAN/CSA-C22.2 No. 60601-2-21, Medical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performance of infant radiant warmers, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 60601-2-21 (second edition, 2009-02). It supersedes the previous edition, published in 1998 as CAN/CSA-C22.2 No. 601.2.21, Medical electrical equipment - Part 2: Particular requirements for the safety of infant radiant warmers (adopted CEI/IEC 601-2-21:1994). It is one in a series of Standards issued by CSA under Part II of the Canadian Electrical Code. Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFANT RADIANT WARMERS as defined in 201.3.204, also referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This particular standard specifies the safety requirements for INFANT RADIANT WARMERS, but alternate methods of compliance with a specific clause, by demonstrating equivalent safety, will not be judged as non-compliant, if the MANUFACTURER has demonstrated in his RISK MANAGEMENT FILE that the RISK presented by the HAZARD has been found to be of an acceptable level when weighed against the benefit of treatment from the device. This particular standard does not apply to: - devices supplying heat via BLANKETS, PADS or MATTRESSES in medical use; for information see IEC 80601-2-35; - INFANT INCUBATORS; for information see IEC 60601-2-19; - INFANT TRANSPORT INCUBATORS, for information see IEC 60601-2-20; - INFANT PHOTOTHERAPY EQUIPMENT, for information see IEC 60601-2-50. ------------------------------------------------------------------------------------------------------------------------------ Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 nº 60601-2-21, Appareils électromédicaux - Partie 2-21 : Exigences particulières pour la sécurité de base et les performances essentielles des incubateurs radiants pour nouveau-nés. Il s'agit de l'adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 60601-2-21 (deuxième édition, 2009-02), qui porte le même titre. Cette norme remplace l'édition précédente publiée en 1998 et intitulée CAN/CSA-C22.2 nº 601.2.21, Appareils électromédicaux - Partie 2 : Règles particulières de sécurité des incubateurs radiants pour nouveau-nés (norme CEI/IEC 601-2-21:1994 adoptée). Cette norme fait partie d'une série de normes publiées par CSA lesquelles constituent le Code canadien de l'électricité, Deuxième partie. Domaine d'application Remplacement: La présente norme internationale s'applique à la SECURITE DE BASE et aux PERFORMANCES ESSENTIELLES des INCUBATEURS RADIANTS POUR NOUVEAU-NES, comme définis dans 201.3.204, également désignés sous le terme APPAREILS EM. Si un article ou un paragraphe est spécifiquement destiné à être applicable uniquement aux APPAREILS EM ou uniquement aux SYSTEMES EM, le titre et le contenu de cet article ou de ce paragraphe l'indiquent. Si tel n'est pas le cas, l'article ou le paragraphe s'applique à la fois aux APPAREILS EM et aux SYSTEMES EM, selon le cas. Les DANGERS inhérents à la fonction physiologique prévue des APPAREILS EM ou des SYSTEMES EM dans le cadre du domaine d'application de la présente norme ne sont pas couverts par des exigences spécifiques contenues dans la présente norme, à l'exception de 7.2.13 et de 8.4.1 de la norme générale. NOTE Voir aussi 4.2 de la norme générale. La présente norme particulière spécifie les exigences de sécurité relatives aux INCUBATEURS RADIANTS POUR NOUVEAU-NES, mais des méthodes alternatives de conformité avec un article spécifique, en démontrant un niveau équivalent de sécurité, ne seront pas jugées comme non conformes, si le FABRICANT a démontré dans son DOSSIER DE GESTION DES RISQUES que le RISQUE présenté par le DANGER s'est révélé avoir un niveau acceptable, lorsqu'il a été évalué par rapport aux avantages du traitement présentés par le dispositif. La présente norme particulière ne s'applique pas: - aux dispositifs délivrant de la chaleur par l'intermédiaire de COUVERTURES, COUSSINS ou MATELAS en usage médical; voir la CEI 80601-2-35 à titre informatif; - aux INCUBATEURS POUR NOUVEAU-NES; voir la CEI 60601-2-19 à titre informatif; - aux INCUBATEURS DE TRANSPORT POUR NOUVEAU-NES; voir la CEI 60601-2-20 à titre informatif; - aux APPAREILS DE PHOTOTHERAPIE POUR NOUVEAU-NES, voir la CEI 60601-2-50 à titre informatif.