Formats Available: Online, Print
Product Overview

CAN/CSA-C22.2 NO. 61010-2-012:17

CSA Group Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-012: Particular requirements for climatic and environmental testing and other temperature conditioning equipment (Adopted 61010-2-012:2016, first edition, 20

Total
As low as $360.00
Select Format Required

More About This Product

Description
Preface This is the first edition of CAN/CSA-C22.2 No. 61010-2-012, Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-012: Particular requirements for climatic and environmental testing and other temperature conditioning equipment, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-012 (first edition, 2016-07). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code.  For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 61010-2-012" throughout.  This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian deviations).  Scope and object This clause of Part 1 is applicable except as follows:  1.1.1 Equipment included in scope  Replacement:  Replace the first paragraph by the following:  This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of their publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.  This Part 2 of IEC 61010 specifies safety requirements for electrical equipment and their accessories within the categories a) through c), wherever they are intended to be used, whenever that equipment incorporates one or more of the following characteristics:    A REFRIGERATING SYSTEM that is acted on or impacted by an integral heating function such that the combined heating and cooling system generates additional and/or more severe HAZARDS than those for the two systems if treated separately.  The materials being treated in the intended application introduce significant heat into the REFRIGERATING SYSTEM that the cooling system in the application yield additional and/or more severe HAZARDS than those for the cooling system if operated at the maximum RATED ambient alone.  An irradiation function for the materials being treated presenting additional HAZARDS.  A function to expose the materials being treated to excessive humidity, carbon dioxide, salt mist, or other substances which may result in additional HAZARDS.  A function of MECHANICAL MOVEMENT presenting additional HAZARDS. Provision for an OPERATOR to walk-in to the operating area to load or unload the materials being treated.  Addition:  Add the following text after the last paragraph:  NOTE 101 Examples of such equipment include environmental testing and plant growth TEST CHAMBERS, refrigerating CIRCULATORS which incorporate heating, recirculating coolers for extracting heat.  If all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard, it should also meet the requirements of those other Part 2 standards. However, when the equipment incorporates only a REFRIGERATING SYSTEM or only a heating function or a combination of the two without introducing additional HAZARDS described in the above dashed paragraphs then the application of IEC 61010-2-011 or IEC 61010-2-010 or both, as applicable, shall be considered instead of this Part 2.  See further information in the flow chart for selection process and guidance in the INTRODUCTION.  NOTE 102 Subclause 3.1.107 and Annex BB provides definition and requirements for protection of people who are inside WALK-IN EQUIPMENT.  1.1.2 Equipment excluded from scope  Addition:  Add the following two new items after item j):  aa) equipment for the heating, cooling, and ventilation of laboratories;  bb) sterilizing equipment.  1.2 Object  1.2.1 Aspects included in scope  Addition:  Add two new items to the list:  aa) biohazards (see 13.101);  bb) hazardous chemical substances (see13.102).  --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------  Préface Ce document constitue la première édition de la CAN/CSA-C22.2 nº 61010-2-012, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-012 : Exigences particulières pour les appareils d'essais climatiques et d'environnement, et autres appareils de conditionnement de température. Il s'agit de l'adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-012 (première édition, 2016-07) qui porte le même titre. Il fait partie d'une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l'électricité, Deuxième partie.  Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 61010-2-012».  Cette norme est conçue pour être utilisée de concert avec la CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada).  Domaine d'application et objet Cet article de la Partie 1 est applicable, à l'exception de ce qui suit:  1.1.1 Appareils inclus dans le domaine d'application  Remplacement:  Remplacer le premier alinéa par le texte suivant:  La présente publication groupée de sécurité est avant tout destinée à être utilisée en tant que norme en matière de sécurité des produits pour les produits cités dans le domaine d'application. Cependant, elle doit également être utilisée par les comités d'études dans le cadre de l'élaboration de leurs publications pour des produits similaires à ceux cités dans le domaine d'application de la présente norme, conformément aux principes établis dans le Guide IEC 104 et le Guide ISO/IEC 51.  La présente Partie 2 de l'IEC 61010 spécifie les exigences de sécurité pour les appareils électriques et leurs accessoires relevant des catégories a) à c) quelle que soit l'utilisation à laquelle ils sont destinés, lorsque ces appareils comprennent une ou plusieurs des caractéristiques suivantes:    Un SYSTEME FRIGORIFIQUE affecté ou influencé par une fonction de chauffage intégrée de sorte que le système de chauffage et de refroidissement combiné engendre des DANGERS supplémentaires et/ou plus graves que ceux pour les deux systèmes s'ils sont traités séparément.  Les matières traitées dans l'application prévue génèrent une chaleur importante dans le SYSTEME FRIGORIFIQUE, de sorte que le système de refroidissement dans l'application engendre des DANGERS supplémentaires et/ou plus graves que ceux pour le système de refroidissement dans le cas où il est utilisé seul à la température ambiante ASSIGNEE maximale.  Une fonction d'exposition aux rayonnements pour les matières traitées qui présentent des DANGERS supplémentaires.  Une fonction dédiée à l'exposition des matières traitées à une humidité excessive, au dioxyde de carbone, au brouillard salin ou à d'autres substances qui peuvent engendrer des DANGERS supplémentaires.  Une fonction de MOUVEMENT MECANIQUE qui présente des DANGERS supplémentaires.  Un dispositif qui permet le déplacement de l'OPERATEUR vers la zone de manoeuvre afin de charger ou décharger les matières traitées.  Addition:  Ajouter le texte suivant après le dernier alinéa:  NOTE 101 Les exemples de ce type d'appareils incluent les enceintes pour essais d'environnement et les ENCEINTES D'ESSAI dédiées à la croissance des plantes, les THERMOSTATS de réfrigération comportant une fonction de chauffage et les refroidisseurs à recirculation pour l'extraction de la chaleur.  Si une ou toutes les parties de lappareil relèvent du domaine d'application d'une ou plusieurs autres Parties 2 de l'IEC 61010, ainsi que du domaine d'application de la présente norme, l'appareil doit également satisfaire aux exigences de ces autres Parties 2. Toutefois, lorsque l'appareil comprend uniquement un SYSTEME FRIGORIFIQUE ou uniquement une fonction de chauffage ou une combinaison des deux sans introduire de DANGERS supplémentaires décrits dans les alinéas pointillés ci-dessus, l'application de l'IEC 61010-2-011 ou de l'IEC 61010-2-010 ou les deux, selon le cas, doit alors être envisagée en lieu et place de cette Partie 2.  Voir d'autres informations dans l'organigramme pour le processus de sélection et le guide dans l'INTRODUCTION.  NOTE 102 Le paragraphe 3.1.107 et l'Annexe BB fournissent la définition et les exigences concernant la protection des personnes qui se trouvent à l'intérieur d'APPAREILS MOBILES.  1.1.2 Appareils exclus du domaine d'application  Addition:  Ajouter les deux points suivants après le point j):  aa) appareils pour le chauffage, le refroidissement et la ventilation des laboratoires;  bb) appareils de stérilisation.  1.2 Objet  1.2.1 Aspects inclus dans le domaine d'application  Addition:  Ajouter deux points à la liste:  aa) dangers biologiques (voir 13.101);  bb) substances chimiques dangereuses (voir 13.102).  
Preface This is the first edition of CAN/CSA-C22.2 No. 61010-2-012, Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-012: Particular requirements for climatic and environmental testing and other temperature conditioning equipment, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-012 (first edition, 2016-07). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code.  For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 61010-2-012" throughout.  This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian deviations).  Scope and object This clause of Part 1 is applicable except as follows:  1.1.1 Equipment included in scope  Replacement:  Replace the first paragraph by the following:  This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of their publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51.  This Part 2 of IEC 61010 specifies safety requirements for electrical equipment and their accessories within the categories a) through c), wherever they are intended to be used, whenever that equipment incorporates one or more of the following characteristics:    A REFRIGERATING SYSTEM that is acted on or impacted by an integral heating function such that the combined heating and cooling system generates additional and/or more severe HAZARDS than those for the two systems if treated separately.  The materials being treated in the intended application introduce significant heat into the REFRIGERATING SYSTEM that the cooling system in the application yield additional and/or more severe HAZARDS than those for the cooling system if operated at the maximum RATED ambient alone.  An irradiation function for the materials being treated presenting additional HAZARDS.  A function to expose the materials being treated to excessive humidity, carbon dioxide, salt mist, or other substances which may result in additional HAZARDS.  A function of MECHANICAL MOVEMENT presenting additional HAZARDS. Provision for an OPERATOR to walk-in to the operating area to load or unload the materials being treated.  Addition:  Add the following text after the last paragraph:  NOTE 101 Examples of such equipment include environmental testing and plant growth TEST CHAMBERS, refrigerating CIRCULATORS which incorporate heating, recirculating coolers for extracting heat.  If all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard, it should also meet the requirements of those other Part 2 standards. However, when the equipment incorporates only a REFRIGERATING SYSTEM or only a heating function or a combination of the two without introducing additional HAZARDS described in the above dashed paragraphs then the application of IEC 61010-2-011 or IEC 61010-2-010 or both, as applicable, shall be considered instead of this Part 2.  See further information in the flow chart for selection process and guidance in the INTRODUCTION.  NOTE 102 Subclause 3.1.107 and Annex BB provides definition and requirements for protection of people who are inside WALK-IN EQUIPMENT.  1.1.2 Equipment excluded from scope  Addition:  Add the following two new items after item j):  aa) equipment for the heating, cooling, and ventilation of laboratories;  bb) sterilizing equipment.  1.2 Object  1.2.1 Aspects included in scope  Addition:  Add two new items to the list:  aa) biohazards (see 13.101);  bb) hazardous chemical substances (see13.102).  --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------  Préface Ce document constitue la première édition de la CAN/CSA-C22.2 nº 61010-2-012, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 2-012 : Exigences particulières pour les appareils d'essais climatiques et d'environnement, et autres appareils de conditionnement de température. Il s'agit de l'adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-012 (première édition, 2016-07) qui porte le même titre. Il fait partie d'une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l'électricité, Deuxième partie.  Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 nº 61010-2-012».  Cette norme est conçue pour être utilisée de concert avec la CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada).  Domaine d'application et objet Cet article de la Partie 1 est applicable, à l'exception de ce qui suit:  1.1.1 Appareils inclus dans le domaine d'application  Remplacement:  Remplacer le premier alinéa par le texte suivant:  La présente publication groupée de sécurité est avant tout destinée à être utilisée en tant que norme en matière de sécurité des produits pour les produits cités dans le domaine d'application. Cependant, elle doit également être utilisée par les comités d'études dans le cadre de l'élaboration de leurs publications pour des produits similaires à ceux cités dans le domaine d'application de la présente norme, conformément aux principes établis dans le Guide IEC 104 et le Guide ISO/IEC 51.  La présente Partie 2 de l'IEC 61010 spécifie les exigences de sécurité pour les appareils électriques et leurs accessoires relevant des catégories a) à c) quelle que soit l'utilisation à laquelle ils sont destinés, lorsque ces appareils comprennent une ou plusieurs des caractéristiques suivantes:    Un SYSTEME FRIGORIFIQUE affecté ou influencé par une fonction de chauffage intégrée de sorte que le système de chauffage et de refroidissement combiné engendre des DANGERS supplémentaires et/ou plus graves que ceux pour les deux systèmes s'ils sont traités séparément.  Les matières traitées dans l'application prévue génèrent une chaleur importante dans le SYSTEME FRIGORIFIQUE, de sorte que le système de refroidissement dans l'application engendre des DANGERS supplémentaires et/ou plus graves que ceux pour le système de refroidissement dans le cas où il est utilisé seul à la température ambiante ASSIGNEE maximale.  Une fonction d'exposition aux rayonnements pour les matières traitées qui présentent des DANGERS supplémentaires.  Une fonction dédiée à l'exposition des matières traitées à une humidité excessive, au dioxyde de carbone, au brouillard salin ou à d'autres substances qui peuvent engendrer des DANGERS supplémentaires.  Une fonction de MOUVEMENT MECANIQUE qui présente des DANGERS supplémentaires.  Un dispositif qui permet le déplacement de l'OPERATEUR vers la zone de manoeuvre afin de charger ou décharger les matières traitées.  Addition:  Ajouter le texte suivant après le dernier alinéa:  NOTE 101 Les exemples de ce type d'appareils incluent les enceintes pour essais d'environnement et les ENCEINTES D'ESSAI dédiées à la croissance des plantes, les THERMOSTATS de réfrigération comportant une fonction de chauffage et les refroidisseurs à recirculation pour l'extraction de la chaleur.  Si une ou toutes les parties de lappareil relèvent du domaine d'application d'une ou plusieurs autres Parties 2 de l'IEC 61010, ainsi que du domaine d'application de la présente norme, l'appareil doit également satisfaire aux exigences de ces autres Parties 2. Toutefois, lorsque l'appareil comprend uniquement un SYSTEME FRIGORIFIQUE ou uniquement une fonction de chauffage ou une combinaison des deux sans introduire de DANGERS supplémentaires décrits dans les alinéas pointillés ci-dessus, l'application de l'IEC 61010-2-011 ou de l'IEC 61010-2-010 ou les deux, selon le cas, doit alors être envisagée en lieu et place de cette Partie 2.  Voir d'autres informations dans l'organigramme pour le processus de sélection et le guide dans l'INTRODUCTION.  NOTE 102 Le paragraphe 3.1.107 et l'Annexe BB fournissent la définition et les exigences concernant la protection des personnes qui se trouvent à l'intérieur d'APPAREILS MOBILES.  1.1.2 Appareils exclus du domaine d'application  Addition:  Ajouter les deux points suivants après le point j):  aa) appareils pour le chauffage, le refroidissement et la ventilation des laboratoires;  bb) appareils de stérilisation.  1.2 Objet  1.2.1 Aspects inclus dans le domaine d'application  Addition:  Ajouter deux points à la liste:  aa) dangers biologiques (voir 13.101);  bb) substances chimiques dangereuses (voir 13.102).