Formats Available: Online, Print
Product Overview

CAN/CSA-C22.2 NO. 61010-2-201:18

CSA Group Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-201: Particular requirements for control equipment (Adopted IEC 61020-2-201:2017, second edition, 2017-03, with Canadian deviations) | Exigences de sécurité

Total
As low as $400.00
Select Format Required

More About This Product

Description
Preface This is the second edition of CAN/CSA-C22.2 No. 61010-2-201, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-201: Particular requirements for control equipment, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-201 (second edition, 2017-03). It supersedes the previous edition published in 2014 as CAN/CSA-IEC 61010-2-201 (adopted IEC 61010-2-201:2013). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code.  For brevity, this Standard will be referred to as “CAN/CSA-C22.2 No. 61010-2-201” throughout.  This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian deviations).  Scope and object This clause of Part 1 is applicable, except as follows.  1.1.1 Equipment included in scope  Replacement:  • This part of IEC 61010 specifies safety requirements and related verification tests for any product performing the function of control equipment and/or their associated peripherals. In addition, these products have as their intended use the command and control of machines, automated manufacturing and industrial processes, e.g. discrete and continuous control. Some equipment examples are: programmable logic controller (PLC);  • programmable automation controller (PAC);  • distributed control systems (DCS);  • remote I/O;  • industrial PC (computers) and panel PC;  • programming and debugging tools (PADTs);  • displays and human-machine interfaces (HMI);  • positioners.  Components of the above named equipment and in the scope of this standard are:  • (auxiliary) stand-alone power supplies;  • peripherals such as digital and analogue I/O, remote-I/O;  • industrial network equipment.  Control equipment and their associated peripherals are intended to be used in an industrial environment and may be provided as OPEN or ENCLOSED EQUIPMENT.  NOTE 1 Control equipment intended also for use in other environments or for other purposes (example: for use in building installations to control light or other electrical installations, or for use on cars, trains or ships) can have additional conformity requirements defined by the safety standard(s) for these applications. These requirements can involve as example: insulation, spacings and power restrictions.  NOTE 2 Computing devices and similar equipment within the scope of IEC 60950 (planned to be replaced by IEC 62368) and conforming to its requirements are considered to be suitable for use with control equipment within the scope of this standard. However, some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in IEC 61010-1:2010, 5.4.4 second paragraph.  Control equipment covered in this standard is intended for use in OVERVOLTAGE CATEGORY II, III and IV (IEC 60664-1) in low-voltage installations, where the RATED equipment supply voltage does not exceed AC. 1 000 V r.m.s. (50/60 Hz), or DC 1 000 V.  The requirements of ISO/IEC Guide 51 and IEC Guide 104, as they relate to this part of IEC 61010, are incorporated herein.  1.1.2 Equipment excluded from scope  Replacement:  This Standard does not deal with aspects of the overall automated system, e.g. a complete assembly line. Control equipment (e.g. DCS and PLC), their application program and their associated peripherals are considered as components (components in this context are items which perform no useful function by themselves) of an overall automated system.  Since control equipment (e.g. DCS and PLC) are component devices, safety considerations for the overall automated system including installation and application are beyond the scope of this standard. Refer to IEC 60364 series of standards or applicable national/local regulations for electrical installation and guidelines.  1.2.1 Aspects included in scope  Replacement:  The purpose of the requirements of this standard is to ensure that all HAZARDs to the OPERATOR, SERVICE PERSONNEL and the surrounding area are reduced to a tolerable level.  NOTE 1 By using the terms "OPERATOR" and "SERVICE PERSONNEL" this standard considers the perception of HAZARDS depending on training and skills. Annex AA gives a general approach in this regard.  Requirements for protection against particular types of HAZARD are given in Clauses 6 to 17, as follows:  a) electric shock or burn (see Clause 6);  b) mechanical HAZARDS (see Clauses 7 and 8);  c) spread of fire from the control equipment (see Clause 9);  d) excessive temperature (see Clause 10);  e) effects of fluids and fluid pressure (see Clause 11);  f) effects of radiation, including lasers sources, and sonic and ultrasonic pressure (see Clause 12);  g) liberated gases, explosion and implosion (see Clause 13);  h) arising from REASONABLY FORESEEABLE MISUSE and ergonomic factors are specified in (see Clause 16);  i) RISK assessment for HAZARDS or environments not fully covered above (see Clause 17).  NOTE 2 Attention is drawn to the existence of additional requirements regarding the health and safety of labour forces.  1.2.2 Aspects excluded from scope  Replacement:  This Standard does not cover:  a) reliability, functionality, performance, or other properties of the control equipment not related to safety;  b) mechanical or climatic requirements for operation, transport or storage;  c) EMC requirements (see e.g. IEC 61326 or IEC 61131-2);  d) protective measures for explosive atmospheres (see e.g. IEC 60079 series);  e) functional safety (see e.g. IEC 61508, IEC 61131-6).  ----------------------------------------------------------------------------- Préface  Ce document constitue la deuxième édition de CAN/CSA-C22.2 nº 61010-2-201, Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 2-201 : Exigences particulières pour les équipements de commande. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-201 (deuxième édition, 2017-03) qui porte le même titre. Cette norme remplace l’édition antérieure publiée en 2014 qui portait la désignation CAN/CSA-IEC 61010-2-201 (norme IEC 61010-2-201:2013 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie.  Par souci de brièveté, tout au long de ce document, il sera appelé « CAN/CSA-C22.2 nº 61010-2-201 ».  Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada).  Domaine d'application et objet L'article de la Partie 1 s'applique avec les exceptions suivantes.  1.1.1 Appareils inclus dans le domaine d'application  Remplacement:  • La présente partie de l'IEC 61010 spécifie les exigences de sécurité et les essais de vérification associés pour les produits remplissant la fonction d'équipements de commande et/ou leurs périphériques associés. L'utilisation prévue de ces produits consiste à contrôler et commander les machines, les processus industriels et de fabrication automatisés, par exemple par le biais d'un contrôle discret et continu. Les équipements suivants en sont des exemples: les automates programmables (PLC, Programmable Logic Controller);  • les contrôleurs d'automatisation programmables (PAC, Programmable Automation Controller);  • les systèmes à commande répartie (DCS, Distributed Control Systems);  • les systèmes d'E/S déportés;  • les ordinateurs (individuels) industriels et combinés PC-écran;  • les outils de programmation et de débogage (PADT, Programming and Debugging Tools);  • les affichages et les interfaces homme/machine (IHM);  • les positionneurs.  Les composants des équipements susmentionnés et relevant du domaine d'application de la présente norme sont:  • les alimentations autonomes (auxiliaires);  • les périphériques tels que les E/S numériques et analogiques, ainsi que les E/S déportés;  • les équipements de réseau industriels.  Les équipements de commande et leurs périphériques associés sont conçus pour être utilisés dans un environnement industriel et peuvent être fournis sous la forme d'EQUIPEMENTS OUVERTS ou SOUS ENVELOPPE.  NOTE 1 Les équipements de commande également conçus pour être utilisés dans d'autres environnements ou à d'autres fins (p. ex.: au sein de bâtiments pour commander l'éclairage ou d'autres installations électriques ou à bord de voitures, trains ou bateaux) peuvent faire l'objet d'exigences de conformité supplémentaires définies par la ou les normes de sécurité applicables à ces applications. Ces exigences peuvent concerner, par exemple, l'isolation, les espacements et les restrictions de puissance.  NOTE 2 Les calculateurs et équipements analogues relevant du domaine d'application de l'IEC 60950 (destiné à être remplacée par l'IEC 62368) et satisfaisant à ses exigences sont réputés être aptes à l'utilisation avec les équipements de commande relevant du domaine d'application de la présente norme. Cependant, certaines des exigences de l'IEC 60950 relative à la tenue à l'humidité et aux liquides sont moins sévères que celles de l'IEC 61010-1:2010, 5.4.4, deuxième alinéa.  Les équipements de commande couverts par la présente norme sont destinés à être utilisés dans des installations à basse tension de CATEGORIE DE SURTENSION II, III et IV (IEC 60664-1), où la tension d'alimentation ASSIGNEE des équipements ne dépasse pas 1 000 V efficace en courant alternatif (50/60 Hz) ou 1 000 V en courant continu.  Les exigences du Guide ISO/IEC 51 et du Guide IEC 104, en rapport avec la présente partie de l'IEC 61010, sont intégrées au présent document.  1.1.2 Appareils exclus du domaine d'application  Remplacement:  La présente norme ne traite pas des aspects du système automatisé global, par exemple une chaîne de montage complète. Les équipements de commande (p. ex.: systèmes à commande distribuée et automates programmables), leurs programmes d'application et leurs périphériques associés sont considérés comme des composants (les composants dans ce contexte sont des éléments qui n'accomplissent aucune fonction utile) d'un système automatisé global.  Etant donné que les équipements de commande (p. ex.: systèmes à commande répartie et automates programmables) sont des appareils de type composants, les considérations relatives à la sécurité du système automatisé global portant sur l'installation et l'application ne relèvent pas du domaine d'application de la présente norme. Se reporter à la série IEC 60364 ou aux règlements nationaux/locaux applicables pour l'installation électrique et les lignes directrices.  1.2.1 Aspects inclus dans le domaine d'application  Remplacement:  Les exigences de la présente norme ont pour objet d'assurer que tous les DANGERS pour l'OPERATEUR, le PERSONNEL D'ENTRETIEN et la zone environnante soient réduits à un niveau acceptable.  NOTE 1 En utilisant les termes "OPERATEUR" et "PERSONNEL D'ENTRETIEN", la présente norme prend en compte la perception des DANGERS en fonction de la formation et des compétences. L'Annexe AA propose une approche générale à cet égard.  Les exigences relatives à la protection contre des types particuliers de DANGERS sont données aux Articles 6 à 17, comme suit:  a) les chocs électriques ou brûlures (voir Article 6);  b) les DANGERS mécaniques (voir Articles 7 et 8);  c) la propagation du feu issu des équipements de commande (voir Article 9);  d) une température excessive (voir Article 10);  e) les effets des fluides et de la pression des fluides (voir Article 11);  f) les effets des radiations, y compris les sources laser, et de la pression acoustique et ultrasonique (voir Article 12);  g) les émissions de gaz, les explosions et les implosions (voir Article 13);  h) les dangers résultant d'un mauvais usage raisonnablement prévisible et des facteurs ergonomiques spécifiés (voir Article 16);  i) une appréciation du RISQUE pour les DANGERS ou environnements qui ne sont pas entièrement couverts ci-dessus (voir Article 17).  NOTE 2 L'attention est attirée sur l'existence d'exigences supplémentaires concernant la santé et la sécurité des personnels.  1.2.2 Aspects exclus du domaine d'application  Remplacement:  La présente norme ne couvre pas:  a) la fiabilité, les fonctionnalités, les performances, ni les autres propriétés de l'équipement de commande qui ne sont pas liées à la sécurité;  b) les exigences mécaniques ou climatiques relatives à l'exploitation, au transport ou à l'entreposage;  c) les exigences relatives à la CEM (p. ex.: IEC 61326 ou IEC 61131-2);  d) les mesures de protection relatives aux atmosphères explosives (p. ex.: série IEC 60079);  e) la sécurité fonctionnelle (p. ex.: IEC 61508 ou IEC 61131-6).  
Preface This is the second edition of CAN/CSA-C22.2 No. 61010-2-201, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-201: Particular requirements for control equipment, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-201 (second edition, 2017-03). It supersedes the previous edition published in 2014 as CAN/CSA-IEC 61010-2-201 (adopted IEC 61010-2-201:2013). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code.  For brevity, this Standard will be referred to as “CAN/CSA-C22.2 No. 61010-2-201” throughout.  This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian deviations).  Scope and object This clause of Part 1 is applicable, except as follows.  1.1.1 Equipment included in scope  Replacement:  • This part of IEC 61010 specifies safety requirements and related verification tests for any product performing the function of control equipment and/or their associated peripherals. In addition, these products have as their intended use the command and control of machines, automated manufacturing and industrial processes, e.g. discrete and continuous control. Some equipment examples are: programmable logic controller (PLC);  • programmable automation controller (PAC);  • distributed control systems (DCS);  • remote I/O;  • industrial PC (computers) and panel PC;  • programming and debugging tools (PADTs);  • displays and human-machine interfaces (HMI);  • positioners.  Components of the above named equipment and in the scope of this standard are:  • (auxiliary) stand-alone power supplies;  • peripherals such as digital and analogue I/O, remote-I/O;  • industrial network equipment.  Control equipment and their associated peripherals are intended to be used in an industrial environment and may be provided as OPEN or ENCLOSED EQUIPMENT.  NOTE 1 Control equipment intended also for use in other environments or for other purposes (example: for use in building installations to control light or other electrical installations, or for use on cars, trains or ships) can have additional conformity requirements defined by the safety standard(s) for these applications. These requirements can involve as example: insulation, spacings and power restrictions.  NOTE 2 Computing devices and similar equipment within the scope of IEC 60950 (planned to be replaced by IEC 62368) and conforming to its requirements are considered to be suitable for use with control equipment within the scope of this standard. However, some of the requirements of IEC 60950 for resistance to moisture and liquids are less stringent than those in IEC 61010-1:2010, 5.4.4 second paragraph.  Control equipment covered in this standard is intended for use in OVERVOLTAGE CATEGORY II, III and IV (IEC 60664-1) in low-voltage installations, where the RATED equipment supply voltage does not exceed AC. 1 000 V r.m.s. (50/60 Hz), or DC 1 000 V.  The requirements of ISO/IEC Guide 51 and IEC Guide 104, as they relate to this part of IEC 61010, are incorporated herein.  1.1.2 Equipment excluded from scope  Replacement:  This Standard does not deal with aspects of the overall automated system, e.g. a complete assembly line. Control equipment (e.g. DCS and PLC), their application program and their associated peripherals are considered as components (components in this context are items which perform no useful function by themselves) of an overall automated system.  Since control equipment (e.g. DCS and PLC) are component devices, safety considerations for the overall automated system including installation and application are beyond the scope of this standard. Refer to IEC 60364 series of standards or applicable national/local regulations for electrical installation and guidelines.  1.2.1 Aspects included in scope  Replacement:  The purpose of the requirements of this standard is to ensure that all HAZARDs to the OPERATOR, SERVICE PERSONNEL and the surrounding area are reduced to a tolerable level.  NOTE 1 By using the terms "OPERATOR" and "SERVICE PERSONNEL" this standard considers the perception of HAZARDS depending on training and skills. Annex AA gives a general approach in this regard.  Requirements for protection against particular types of HAZARD are given in Clauses 6 to 17, as follows:  a) electric shock or burn (see Clause 6);  b) mechanical HAZARDS (see Clauses 7 and 8);  c) spread of fire from the control equipment (see Clause 9);  d) excessive temperature (see Clause 10);  e) effects of fluids and fluid pressure (see Clause 11);  f) effects of radiation, including lasers sources, and sonic and ultrasonic pressure (see Clause 12);  g) liberated gases, explosion and implosion (see Clause 13);  h) arising from REASONABLY FORESEEABLE MISUSE and ergonomic factors are specified in (see Clause 16);  i) RISK assessment for HAZARDS or environments not fully covered above (see Clause 17).  NOTE 2 Attention is drawn to the existence of additional requirements regarding the health and safety of labour forces.  1.2.2 Aspects excluded from scope  Replacement:  This Standard does not cover:  a) reliability, functionality, performance, or other properties of the control equipment not related to safety;  b) mechanical or climatic requirements for operation, transport or storage;  c) EMC requirements (see e.g. IEC 61326 or IEC 61131-2);  d) protective measures for explosive atmospheres (see e.g. IEC 60079 series);  e) functional safety (see e.g. IEC 61508, IEC 61131-6).  ----------------------------------------------------------------------------- Préface  Ce document constitue la deuxième édition de CAN/CSA-C22.2 nº 61010-2-201, Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 2-201 : Exigences particulières pour les équipements de commande. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-201 (deuxième édition, 2017-03) qui porte le même titre. Cette norme remplace l’édition antérieure publiée en 2014 qui portait la désignation CAN/CSA-IEC 61010-2-201 (norme IEC 61010-2-201:2013 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie.  Par souci de brièveté, tout au long de ce document, il sera appelé « CAN/CSA-C22.2 nº 61010-2-201 ».  Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada).  Domaine d'application et objet L'article de la Partie 1 s'applique avec les exceptions suivantes.  1.1.1 Appareils inclus dans le domaine d'application  Remplacement:  • La présente partie de l'IEC 61010 spécifie les exigences de sécurité et les essais de vérification associés pour les produits remplissant la fonction d'équipements de commande et/ou leurs périphériques associés. L'utilisation prévue de ces produits consiste à contrôler et commander les machines, les processus industriels et de fabrication automatisés, par exemple par le biais d'un contrôle discret et continu. Les équipements suivants en sont des exemples: les automates programmables (PLC, Programmable Logic Controller);  • les contrôleurs d'automatisation programmables (PAC, Programmable Automation Controller);  • les systèmes à commande répartie (DCS, Distributed Control Systems);  • les systèmes d'E/S déportés;  • les ordinateurs (individuels) industriels et combinés PC-écran;  • les outils de programmation et de débogage (PADT, Programming and Debugging Tools);  • les affichages et les interfaces homme/machine (IHM);  • les positionneurs.  Les composants des équipements susmentionnés et relevant du domaine d'application de la présente norme sont:  • les alimentations autonomes (auxiliaires);  • les périphériques tels que les E/S numériques et analogiques, ainsi que les E/S déportés;  • les équipements de réseau industriels.  Les équipements de commande et leurs périphériques associés sont conçus pour être utilisés dans un environnement industriel et peuvent être fournis sous la forme d'EQUIPEMENTS OUVERTS ou SOUS ENVELOPPE.  NOTE 1 Les équipements de commande également conçus pour être utilisés dans d'autres environnements ou à d'autres fins (p. ex.: au sein de bâtiments pour commander l'éclairage ou d'autres installations électriques ou à bord de voitures, trains ou bateaux) peuvent faire l'objet d'exigences de conformité supplémentaires définies par la ou les normes de sécurité applicables à ces applications. Ces exigences peuvent concerner, par exemple, l'isolation, les espacements et les restrictions de puissance.  NOTE 2 Les calculateurs et équipements analogues relevant du domaine d'application de l'IEC 60950 (destiné à être remplacée par l'IEC 62368) et satisfaisant à ses exigences sont réputés être aptes à l'utilisation avec les équipements de commande relevant du domaine d'application de la présente norme. Cependant, certaines des exigences de l'IEC 60950 relative à la tenue à l'humidité et aux liquides sont moins sévères que celles de l'IEC 61010-1:2010, 5.4.4, deuxième alinéa.  Les équipements de commande couverts par la présente norme sont destinés à être utilisés dans des installations à basse tension de CATEGORIE DE SURTENSION II, III et IV (IEC 60664-1), où la tension d'alimentation ASSIGNEE des équipements ne dépasse pas 1 000 V efficace en courant alternatif (50/60 Hz) ou 1 000 V en courant continu.  Les exigences du Guide ISO/IEC 51 et du Guide IEC 104, en rapport avec la présente partie de l'IEC 61010, sont intégrées au présent document.  1.1.2 Appareils exclus du domaine d'application  Remplacement:  La présente norme ne traite pas des aspects du système automatisé global, par exemple une chaîne de montage complète. Les équipements de commande (p. ex.: systèmes à commande distribuée et automates programmables), leurs programmes d'application et leurs périphériques associés sont considérés comme des composants (les composants dans ce contexte sont des éléments qui n'accomplissent aucune fonction utile) d'un système automatisé global.  Etant donné que les équipements de commande (p. ex.: systèmes à commande répartie et automates programmables) sont des appareils de type composants, les considérations relatives à la sécurité du système automatisé global portant sur l'installation et l'application ne relèvent pas du domaine d'application de la présente norme. Se reporter à la série IEC 60364 ou aux règlements nationaux/locaux applicables pour l'installation électrique et les lignes directrices.  1.2.1 Aspects inclus dans le domaine d'application  Remplacement:  Les exigences de la présente norme ont pour objet d'assurer que tous les DANGERS pour l'OPERATEUR, le PERSONNEL D'ENTRETIEN et la zone environnante soient réduits à un niveau acceptable.  NOTE 1 En utilisant les termes "OPERATEUR" et "PERSONNEL D'ENTRETIEN", la présente norme prend en compte la perception des DANGERS en fonction de la formation et des compétences. L'Annexe AA propose une approche générale à cet égard.  Les exigences relatives à la protection contre des types particuliers de DANGERS sont données aux Articles 6 à 17, comme suit:  a) les chocs électriques ou brûlures (voir Article 6);  b) les DANGERS mécaniques (voir Articles 7 et 8);  c) la propagation du feu issu des équipements de commande (voir Article 9);  d) une température excessive (voir Article 10);  e) les effets des fluides et de la pression des fluides (voir Article 11);  f) les effets des radiations, y compris les sources laser, et de la pression acoustique et ultrasonique (voir Article 12);  g) les émissions de gaz, les explosions et les implosions (voir Article 13);  h) les dangers résultant d'un mauvais usage raisonnablement prévisible et des facteurs ergonomiques spécifiés (voir Article 16);  i) une appréciation du RISQUE pour les DANGERS ou environnements qui ne sont pas entièrement couverts ci-dessus (voir Article 17).  NOTE 2 L'attention est attirée sur l'existence d'exigences supplémentaires concernant la santé et la sécurité des personnels.  1.2.2 Aspects exclus du domaine d'application  Remplacement:  La présente norme ne couvre pas:  a) la fiabilité, les fonctionnalités, les performances, ni les autres propriétés de l'équipement de commande qui ne sont pas liées à la sécurité;  b) les exigences mécaniques ou climatiques relatives à l'exploitation, au transport ou à l'entreposage;  c) les exigences relatives à la CEM (p. ex.: IEC 61326 ou IEC 61131-2);  d) les mesures de protection relatives aux atmosphères explosives (p. ex.: série IEC 60079);  e) la sécurité fonctionnelle (p. ex.: IEC 61508 ou IEC 61131-6).