Formats Available: Online, Print
Product Overview

CAN/CSA-C61000-2-7-04 (R2017)

CSA Group Electromagnetic Compatibility (EMC) - Part 2: Environment - Section 7: Low Frequency Magnetic Fields in Various Environments (Adopted CEI/IEC 61000-2-7:1998, first edition, 1998-01, with Canadian deviations) | Compatibilité électromagnétique (CEM) - Parti

Total
As low as $168.00
Select Format Required

More About This Product

Description
Scope Interest in magnetic fields has been stimulated in recent years by concern over the physiological effects they may have on humans and animals and the deleterious effects they have on the performance of some electrical equipment, particularly video display units. Investigations have yielded results which are presented in this report as reference values.  Note 1 - The European Union EMC Directive has prompted magnetic field measurements, particularly in respect of the commercial office environments associated with supply authority substations and electrical distribution systems within buildings. Supply authorities have sponsored most of the work and the results are generally within the frequency range of 50 Hz to 2 kHz, and presented as r.m.s. values. There is, however, a need to have some knowledge about d.c. fields and the fields up to 150 kHz as they may interfere with some types of equipment.  Note 2 - Most of the magnetic field data in this report is associated with sinusoidal current sources and r.m.s. values may be assumed unless otherwise stated. Power supply systems operating at voltages less than or equal to 1 000 V are designated low-voltage, those above 1 000 V and up to 35 kV are designated medium-voltage, and those in excess of 35 kV are designated high-voltage.  --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------  Domaine d’application Les champs magnétiques ont été l'objet d'un regain d'intérêt au cours de ces dernières années en raison des effets physiologiques qu'ils peuvent avoir sur les êtres humains et les animaux et des effets défavorables qu'ils ont sur le fonctionnement de certains équipements électriques, notamment les écrans de visualisation. Les résultats des recherches sont présentés dans ce rapport comme valeurs de référence.  NOTE 1 - La Directive CEM de la Commission Européenne a suscité de faire des mesures de champs magnétiques, particulièrement dans des environnements de bureaux commerciaux à proximité de postes appartenant à des compagnies d'électricité ainsi que dans des environnements de réseaux de distribution d'électricité à l'intérieur des bâtiments. Les distributeurs d'électricité ont supporté financièrement la plupart des travaux et les résultats se situent généralement dans la gamme de fréquence allant de 50 Hz à 2 kHz et sont présentés comme des valeurs efficaces. Il est toutefois nécessaire de connaître quelque peu les champs magnétiques jusqu'à 150 kHz car ils interfèrent avec certains types d'appareils.  NOTE 2 - La plupart des valeurs de champs magnétiques indiquées dans ce rapport correspondent à des sources de courant sinusoïdal et on peut les considérer comme des valeurs efficaces sauf indications contraires. Les réseaux d'alimentation de tensions inférieures ou égales à 1 000 V sont considérés comme des réseaux basse tension, ceux exploités à des tensions supérieures à 1 000 V allant jusqu'à 35 kV comme des réseaux moyenne tension et enfin ceux exploités à des tensions supérieures à 35 kV comme des réseaux haute tension.
Scope Interest in magnetic fields has been stimulated in recent years by concern over the physiological effects they may have on humans and animals and the deleterious effects they have on the performance of some electrical equipment, particularly video display units. Investigations have yielded results which are presented in this report as reference values.  Note 1 - The European Union EMC Directive has prompted magnetic field measurements, particularly in respect of the commercial office environments associated with supply authority substations and electrical distribution systems within buildings. Supply authorities have sponsored most of the work and the results are generally within the frequency range of 50 Hz to 2 kHz, and presented as r.m.s. values. There is, however, a need to have some knowledge about d.c. fields and the fields up to 150 kHz as they may interfere with some types of equipment.  Note 2 - Most of the magnetic field data in this report is associated with sinusoidal current sources and r.m.s. values may be assumed unless otherwise stated. Power supply systems operating at voltages less than or equal to 1 000 V are designated low-voltage, those above 1 000 V and up to 35 kV are designated medium-voltage, and those in excess of 35 kV are designated high-voltage.  --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------  Domaine d’application Les champs magnétiques ont été l'objet d'un regain d'intérêt au cours de ces dernières années en raison des effets physiologiques qu'ils peuvent avoir sur les êtres humains et les animaux et des effets défavorables qu'ils ont sur le fonctionnement de certains équipements électriques, notamment les écrans de visualisation. Les résultats des recherches sont présentés dans ce rapport comme valeurs de référence.  NOTE 1 - La Directive CEM de la Commission Européenne a suscité de faire des mesures de champs magnétiques, particulièrement dans des environnements de bureaux commerciaux à proximité de postes appartenant à des compagnies d'électricité ainsi que dans des environnements de réseaux de distribution d'électricité à l'intérieur des bâtiments. Les distributeurs d'électricité ont supporté financièrement la plupart des travaux et les résultats se situent généralement dans la gamme de fréquence allant de 50 Hz à 2 kHz et sont présentés comme des valeurs efficaces. Il est toutefois nécessaire de connaître quelque peu les champs magnétiques jusqu'à 150 kHz car ils interfèrent avec certains types d'appareils.  NOTE 2 - La plupart des valeurs de champs magnétiques indiquées dans ce rapport correspondent à des sources de courant sinusoïdal et on peut les considérer comme des valeurs efficaces sauf indications contraires. Les réseaux d'alimentation de tensions inférieures ou égales à 1 000 V sont considérés comme des réseaux basse tension, ceux exploités à des tensions supérieures à 1 000 V allant jusqu'à 35 kV comme des réseaux moyenne tension et enfin ceux exploités à des tensions supérieures à 35 kV comme des réseaux haute tension.