Formats Available: Online, Print
Product Overview

CAN/CSA-E1048-98 (R2018)

CSA Group Capacitors for Use in Tubular Fluorescent and Other Discharge Lamp Circuits - General and Safety Requirements (Adopted IEC 1048:1991, first edition, 1991-02, including corrigendum 1992 and Amendment 1:1995, with Canadian deviations) | Condensateurs destin

Total
As low as $133.00
Select Format Required

More About This Product

Description
Scope This International Standard states the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2.5 kvar, and not less than 0.1 µF, having a rated voltage not exceeding 1 000 V, which are intended for use in discharge lamp circuits operating at 50 Hz or 60 Hz and at altitudes up to 3 000 m. It covers capacitors intended for connection in shunt or in series with the lamp circuit or an effective combination of these. It covers only impregnated or unimpregnated capacitors, having a dielectric of paper, plastic film or a combination of both, either metallized or with metal foil electrodes. This standard does not cover radio-interference suppressor capacitors the requirements for which are found in IEC 384-14. Tests given in this standard are type tests. Requirements for testing individual capacitors during production are not included. -------------------------------------------------------------------------------------------------------------------------------- Domaine d'application La présente Norme internationale énonce les exigences pour les condensateurs auto régénérateurs et non auto régénérateurs pour usage permanent en courant alternatif, d'une puissance inférieure ou égale à 2,5 kvar, de capacité supérieure à 0,1 µF et dont la tension assignée n'excède pas 1 000 V, qui sont destinés à être utilisés dans les circuits de lampes à décharge fonctionnant à 50 Hz ou 60 Hz à des altitudes jusqu'à 3 000 m. Elle couvre les condensateurs prévus pour le branchement shunt ou en série avec le circuit de lampe, ou une combinaison fonctionnelle des deux. Elle couvre seulement les condensateurs imprégnés ou non imprégnés, ayant un diélectrique en papier, en film plastique ou une combinaison des deux, soit métallisés ou avec des électrodes en feuilles métalliques. Cette norme ne couvre pas les condensateurs d'antiparasitage, dont les prescriptions se trouvent dans la CEI 384-14. Les essais figurant dans cette norme sont des essais de type. Les prescriptions pour l'essai individuel des condensateurs en cours de production ne sont pas incluses.
Scope This International Standard states the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2.5 kvar, and not less than 0.1 µF, having a rated voltage not exceeding 1 000 V, which are intended for use in discharge lamp circuits operating at 50 Hz or 60 Hz and at altitudes up to 3 000 m. It covers capacitors intended for connection in shunt or in series with the lamp circuit or an effective combination of these. It covers only impregnated or unimpregnated capacitors, having a dielectric of paper, plastic film or a combination of both, either metallized or with metal foil electrodes. This standard does not cover radio-interference suppressor capacitors the requirements for which are found in IEC 384-14. Tests given in this standard are type tests. Requirements for testing individual capacitors during production are not included. -------------------------------------------------------------------------------------------------------------------------------- Domaine d'application La présente Norme internationale énonce les exigences pour les condensateurs auto régénérateurs et non auto régénérateurs pour usage permanent en courant alternatif, d'une puissance inférieure ou égale à 2,5 kvar, de capacité supérieure à 0,1 µF et dont la tension assignée n'excède pas 1 000 V, qui sont destinés à être utilisés dans les circuits de lampes à décharge fonctionnant à 50 Hz ou 60 Hz à des altitudes jusqu'à 3 000 m. Elle couvre les condensateurs prévus pour le branchement shunt ou en série avec le circuit de lampe, ou une combinaison fonctionnelle des deux. Elle couvre seulement les condensateurs imprégnés ou non imprégnés, ayant un diélectrique en papier, en film plastique ou une combinaison des deux, soit métallisés ou avec des électrodes en feuilles métalliques. Cette norme ne couvre pas les condensateurs d'antiparasitage, dont les prescriptions se trouvent dans la CEI 384-14. Les essais figurant dans cette norme sont des essais de type. Les prescriptions pour l'essai individuel des condensateurs en cours de production ne sont pas incluses.