CSA/ANSI Z21.88:19 (reaffirmed 2024) • CSA 2.33:19 (reaffirmed 2024) National Standard of Canada American National Standard Vented gas fireplace heaters

CSA Group CSA/ANSI Z21.88:19 (reaffirmed 2024) • CSA 2.33:19 (reaffirmed 2024) National Standard of Canada American National Standard Vented gas fireplace heaters

Total
As low as $838.00
Select Format Required

More About This Product

Description

Preface

This is the ninth edition of CSA/ANSI Z21.88 • CSA 2.33, Vented gas fireplace heaters. It supersedes the previous editions published in 2017, 2016, 2014, 2009, 2005, 2002, 2000, and 1998.

This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.

This Standard was prepared by the Joint Technical Subcommittee on Vented Gas-Fired Warm Air Heaters under the jurisdiction of the Z21/83 Technical Committee on Performance and Installation of Gas Burning Appliances and Related Accessories and the Strategic Steering Committee on Fuels and Appliances. It has been formally approved by the Z21/83 Technical Committee, the Canadian Technical Committee on Gas Appliances and Related Accessories, and the Interprovincial Gas Advisory Council.

This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.

This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard.

Interpretations: The Strategic Steering Committee on Fuels and Appliances has provided the following direction for the interpretation of standards under its jurisdiction: “The literal text shall be used in judging compliance of products with the safety requirements of this Standard. When the literal text cannot be applied to the product, such as for new materials or construction, and when a relevant CSA committee interpretation has not already been published, CSA Group’s procedures for interpretation shall be followed to determine the intended safety principle.”

Notes:

1) Use of the singular does not exclude the plural (and vice versa) when the sense allows.

2) Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose.

3) This Standard was developed by consensus, which is defined by CSA Policy governing standardization — Code of good practice for standardization as “substantial agreement. Consensus implies much more than a simple majority, but not necessarily unanimity”. It is consistent with this definition that a member may be included in the Technical Committee list and yet not be in full agreement with all clauses of this Standard.

4) To submit a request for interpretation of this Standard, please send the following information to [email protected] and include “Request for interpretation” in the subject line:

a) define the problem, making reference to the specific clause, and, where appropriate, include an illustrative sketch;

b) provide an explanation of circumstances surrounding the actual field condition; and

c) where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the issue.

Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standardization and are available on the Current Standards Activities page at standardsactivities.csagroup.org.

5) This Standard is subject to review within five years from the date of publication. Suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to [email protected] and include “Proposal for change” in the subject line:

a) Standard designation (number);

b) relevant clause, table, and/or figure number;

c) wording of the proposed change; and

d) rationale for the change.

1 Scope

1.1

This Standard applies to newly produced vented gas fireplace heaters (see Clause 3, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W):

a) for use with natural gas;

b) for use with propane;

c) direct vent appliances for manufactured home (USA only) or mobile home OEM installation convertible for use with natural gas and propane when provision is made for simple conversion from one gas to the other [see Clause 4.1.4a) and b)];

d) direct vent appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only [see Clause 4.1.4b)];

e) direct vent appliances for recreational vehicle installation for use with propane gas only [see Clause 4.1.4c)];

f) direct vent appliances for recreational vehicle installation only convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other [see Clause 4.1.4c)]; and

g) for direct vent appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only [see Clause 4.1.4a)].

The construction of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 4, Construction.

The performance of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 5, Performance.

1.2

Clauses 4 and 5 cover all vented gas fireplace heaters. In addition, Clauses 6 and 7 address the requirements specific to vented condensing gas fireplace heaters.

∆ 1.3

Annex A, Automatic intermittent pilot ignition systems or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on-demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials, to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance.

1.4

If a value for measurement given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.5

All references to “psi” throughout this Standard are to be considered gauge pressures, unless otherwise specified.

1.6

Clause 9, Items unique to the United States, contains provisions that are unique to the United States.

1.7

Clause 10, Items unique to Canada, contains provisions that are unique to Canada.

1.8

This Standard also applies to appliances with draft hoods that are factory-equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices.

1.9

Special construction provisions applicable to vented gas fireplace heaters designed for use with an optional design-certified conversion kit are outlined under Annex B, Provisions for listed gas appliance conversion kits (optional).

1.10

Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained.

1.11

In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

Preface

This is the ninth edition of CSA/ANSI Z21.88 • CSA 2.33, Vented gas fireplace heaters. It supersedes the previous editions published in 2017, 2016, 2014, 2009, 2005, 2002, 2000, and 1998.

This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard.

This Standard was prepared by the Joint Technical Subcommittee on Vented Gas-Fired Warm Air Heaters under the jurisdiction of the Z21/83 Technical Committee on Performance and Installation of Gas Burning Appliances and Related Accessories and the Strategic Steering Committee on Fuels and Appliances. It has been formally approved by the Z21/83 Technical Committee, the Canadian Technical Committee on Gas Appliances and Related Accessories, and the Interprovincial Gas Advisory Council.

This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group.

This Standard has been approved by the American National Standards Institute (ANSI) as an American National Standard.

Interpretations: The Strategic Steering Committee on Fuels and Appliances has provided the following direction for the interpretation of standards under its jurisdiction: “The literal text shall be used in judging compliance of products with the safety requirements of this Standard. When the literal text cannot be applied to the product, such as for new materials or construction, and when a relevant CSA committee interpretation has not already been published, CSA Group’s procedures for interpretation shall be followed to determine the intended safety principle.”

Notes:

1) Use of the singular does not exclude the plural (and vice versa) when the sense allows.

2) Although the intended primary application of this Standard is stated in its Scope, it is important to note that it remains the responsibility of the users of the Standard to judge its suitability for their particular purpose.

3) This Standard was developed by consensus, which is defined by CSA Policy governing standardization — Code of good practice for standardization as “substantial agreement. Consensus implies much more than a simple majority, but not necessarily unanimity”. It is consistent with this definition that a member may be included in the Technical Committee list and yet not be in full agreement with all clauses of this Standard.

4) To submit a request for interpretation of this Standard, please send the following information to [email protected] and include “Request for interpretation” in the subject line:

a) define the problem, making reference to the specific clause, and, where appropriate, include an illustrative sketch;

b) provide an explanation of circumstances surrounding the actual field condition; and

c) where possible, phrase the request in such a way that a specific “yes” or “no” answer will address the issue.

Committee interpretations are processed in accordance with the CSA Directives and guidelines governing standardization and are available on the Current Standards Activities page at standardsactivities.csagroup.org.

5) This Standard is subject to review within five years from the date of publication. Suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to [email protected] and include “Proposal for change” in the subject line:

a) Standard designation (number);

b) relevant clause, table, and/or figure number;

c) wording of the proposed change; and

d) rationale for the change.

1 Scope

1.1

This Standard applies to newly produced vented gas fireplace heaters (see Clause 3, Definitions), hereinafter referred to as appliance(s), constructed entirely of new, unused parts and materials, and having input ratings up to and including 400,000 Btu/hr (117 228 W):

a) for use with natural gas;

b) for use with propane;

c) direct vent appliances for manufactured home (USA only) or mobile home OEM installation convertible for use with natural gas and propane when provision is made for simple conversion from one gas to the other [see Clause 4.1.4a) and b)];

d) direct vent appliances for manufactured home (USA only) or mobile home aftermarket installation for use with natural gas only or propane gas only [see Clause 4.1.4b)];

e) direct vent appliances for recreational vehicle installation for use with propane gas only [see Clause 4.1.4c)];

f) direct vent appliances for recreational vehicle installation only convertible for use with natural gas and propane gas when provision is made for the simple conversion from one gas to the other [see Clause 4.1.4c)]; and

g) for direct vent appliances for manufactured home (USA only) or mobile home OEM installation for use with propane gas only [see Clause 4.1.4a)].

The construction of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 4, Construction.

The performance of vented gas fireplace heaters and vented gas fireplace heaters with cooling units for use with the above-mentioned gases is covered under Clause 5, Performance.

1.2

Clauses 4 and 5 cover all vented gas fireplace heaters. In addition, Clauses 6 and 7 address the requirements specific to vented condensing gas fireplace heaters.

∆ 1.3

Annex A, Automatic intermittent pilot ignition systems or on-demand pilot ignition systems for field installation, includes provisions for newly produced (optional) automatic intermittent pilot ignition systems and on-demand pilot ignition systems (see Clause 3, Definitions), constructed entirely of new, unused parts and materials, to be adapted in the field to an appliance equipped with an existing continuous pilot burner and which has been examined and tested for compliance with this Standard when installed on the appliance.

1.4

If a value for measurement given in this standard is followed by an equivalent value in other units, the first stated value is to be regarded as the specification.

1.5

All references to “psi” throughout this Standard are to be considered gauge pressures, unless otherwise specified.

1.6

Clause 9, Items unique to the United States, contains provisions that are unique to the United States.

1.7

Clause 10, Items unique to Canada, contains provisions that are unique to Canada.

1.8

This Standard also applies to appliances with draft hoods that are factory-equipped with automatic vent damper devices (see Clause 3, Definitions), hereinafter referred to as vent damper devices.

1.9

Special construction provisions applicable to vented gas fireplace heaters designed for use with an optional design-certified conversion kit are outlined under Annex B, Provisions for listed gas appliance conversion kits (optional).

1.10

Clause 2, Reference publications, contains a list of standards specifically referenced in this Standard and sources from which they may be obtained.

1.11

In this Standard, “shall” is used to express a requirement, i.e., a provision that the user shall satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.