Receive access to an electronic copy viewable in a web browser or the Orderline Reader app (Click here to view a demo)
Orderline Reader app available for Windows, Mac, Android, and iOS (Click here to download)
Offline access via Orderline Reader app
Reflowable layout suitable for viewing on any device Orderline Reader app
Font-size controls
Text to speech
Built-in search feature
Google and Wikipedia lookup
Ability to add custom highlights, bookmarks, and notes
Can be registered on up to 3 personal devices total (example: computer, laptop, phone)
Receive access to an online PDF copy viewable in a web browser
Offline access via bookmark to a cached web page
Single user access on up to 3 devices
All online copies are watermarked with your license information
Receive access to an online course viewable in a web browser
Receive access to an online course viewable in a web browser
Receive access to an interactive online copy viewable in a web browser (Click here to view a demo)
Searchable
Printable
Expandable images
Drop-down definitions
Links
Receive access to an online webinar hosted through Zoom
Product Overview
O118.2-08 (R2018)
CSA Group
Eastern White Cedar Shingles
Total
As low as$125.00
More About This Product
Description
Preface This is the second edition of CSA O118.2, Eastern white cedar shingles. It supersedes the previous edition published in 1981 and replaces CSA O118.2-M1981, Eastern White Cedar Shingles. Scope 1.1 This Standard applies to shingles manufactured from eastern white cedar (Thuja occidentalis L.). It specifies minimum grading, manufacturing, packaging, labelling, and conformity assessment requirements. Note: See Annex A for a suggested conformity assessment program for use by third-party inspection and certification agencies and Annex B for recommendations on the use of shingles (including rebutted-rejointed shingles). 1.2 The sizes specified in this Standard are for shingles before drying unless otherwise indicated. 1.3 This Standard does not apply to shingles that have been remanufactured as shims. 1.4 This Standard is a manufacturing Standard and does not apply to installed shingles. 1.5 Where this Standard refers to "hingles" the terminology is also intended to include rebutted-rejointed shingles unless the context indicates otherwise. 1.6 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.7 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.
Preface This is the second edition of CSA O118.2, Eastern white cedar shingles. It supersedes the previous edition published in 1981 and replaces CSA O118.2-M1981, Eastern White Cedar Shingles. Scope 1.1 This Standard applies to shingles manufactured from eastern white cedar (Thuja occidentalis L.). It specifies minimum grading, manufacturing, packaging, labelling, and conformity assessment requirements. Note: See Annex A for a suggested conformity assessment program for use by third-party inspection and certification agencies and Annex B for recommendations on the use of shingles (including rebutted-rejointed shingles). 1.2 The sizes specified in this Standard are for shingles before drying unless otherwise indicated. 1.3 This Standard does not apply to shingles that have been remanufactured as shims. 1.4 This Standard is a manufacturing Standard and does not apply to installed shingles. 1.5 Where this Standard refers to "hingles" the terminology is also intended to include rebutted-rejointed shingles unless the context indicates otherwise. 1.6 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.7 The values given in SI (metric) units are the standard. The values given in parentheses are for information only.