CAN/CSA-C22.2 NO. 61010-2-081:15

CSA Group Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes (Adopted IEC 61010-2-081:2015, second edit

Total
As low as $160.00
Select Format Required

More About This Product

Description
Preface This is the second edition of CAN/CSA-C22.2 No. 61010-2-081, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-081 (second edition, 2015-01). It supersedes the previous edition published in 2004 as CAN/CSA-C22.2 No. 61010-2-081 (adopted IEC 61010-2-081:2001). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 61010-2-081" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1-12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian deviations).   Scope and object This clause of part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the text by the following: This part of IEC 61010 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a system is within the scope of this standard. Examples of equipment within the scope of this standard include: - analytical equipment; - automatic sampler (pipettor, aliquoter); - equipment for sample replication and amplification. NOTE 1 In the case of analytical equipment the complete process usually includes the following steps: - taking a specific quantity of the sample; - preparing the sample by chemical, thermal, mechanical or other means; - measurement; - display, transmission or printing of the results of measurement. NOTE 2 If all or part of the equipment falls within the scope of one or more other part 2 standards of IEC 61010 as well as within the scope of this standard, considerations have to be given to those other part 2 standards. 1.1.2 Equipment excluded from scope Addition: Add the following item: aa) IEC 61010-2-101 (IVD Equipment) 1.2 Object 1.2.1 Aspects included in scope Addition: Add the following items: aa) biohazards; bb) hazardous chemical substances. 1.2.2 Aspects excluded from scope Addition: Add the following item and note: aa) handling or manipulation of material outside the equipment. NOTE Requirements covering these subjects are the responsibility of committees preparing the relevant standards. --------------------------------------------------------------------------------------------------------------------------------   Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 no 61010-2-081, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 2-081 : Exigences particulières pour les appareils de laboratoire, automatiques et semi-automatiques, destinés à l’analyse et autres usages. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-081 (deuxième édition, 2015-01) qui porte le même titre. Cette norme remplace l’édition antérieure publiée en 2004 qui portait la désignation CAN/CSA-C22.2 no 61010-2-081 (norme IEC 61010-2-081:2002 adoptée). Cette norme fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 no 61010-2-081». Cette norme doit être utilisée de concert avec la CAN/CSA-C22.2 no 61010-1-12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada). Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme.   Domaine d’application et objet Cet article de la Partie 1 est applicable, à l'exception de ce qui suit: 1.1.1 Appareils inclus dans le domaine d’application Remplacement: Remplacer le texte par ce qui suit: La présente partie de l’IEC 61010 s’applique aux appareils de laboratoire, automatiques et semi-automatiques, destinés à l’analyse et autres usages. Les appareils de laboratoire automatiques et semi-automatiques comprennent les instruments ou systèmes utilisés pour mesurer ou modifier un ou plusieurs paramètres ou caractéristiques d'échantillons, réalisant tout ou partie du processus sans intervention manuelle. Les équipements faisant partie d'un tel système sont couverts par le domaine d'application de la présente norme. Exemples d'équipements entrant dans le domaine d'application de la présente norme: - équipement réalisant des analyses; - échantillonneur automatique (pipeteur, aliquoteur); - équipement réalisant la réplication ou l'amplification d'échantillon. NOTE 1 En ce qui concerne les équipements réalisant des analyses, le processus complet comprend habituellement les phases suivantes: - prélèvement d’une quantité déterminée de l’échantillon; - préparation de l’échantillon par des moyens chimiques, thermiques, mécaniques ou autres; - mesurage; - affichage, transmission ou impression des résultats de mesurage. NOTE 2 Si l'équipement dans sa totalité ou quelques-uns de ses sous-ensembles relèvent du domaine d’application d’une ou plusieurs autres Parties 2 de la norme IEC 61010 ainsi que du domaine d’application de la présente norme, ces autres Parties 2 doivent également être prises en considération. 1.1.2 Aspects exclus du domaine d’application Addition: Ajouter le point suivant: aa) IEC 61010-2-101 (appareils DIV) 1.2 Objet 1.2.1 Aspects inclus dans le domaine d’application Addition: Ajouter les points suivants: aa) dangers biologiques; bb) produits chimiques dangereux. 1.2.2 Aspects exclus du domaine d’application Addition: Ajouter le point et la note suivants: aa) la manutention ou la manipulation de substances en dehors de l'équipement. NOTE Les exigences applicables à ces sujets sont de la responsabilité des comités préparant les normes appropriées.
Preface This is the second edition of CAN/CSA-C22.2 No. 61010-2-081, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-081: Particular requirements for automatic and semi-automatic laboratory equipment for analysis and other purposes, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-081 (second edition, 2015-01). It supersedes the previous edition published in 2004 as CAN/CSA-C22.2 No. 61010-2-081 (adopted IEC 61010-2-081:2001). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as "CAN/CSA-C22.2 No. 61010-2-081" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1-12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian deviations).   Scope and object This clause of part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the text by the following: This part of IEC 61010 applies to automatic and semi-automatic laboratory equipment for analysis and other purposes. Automatic and semi-automatic laboratory equipment consists of instruments or systems for measuring or modifying one or more characteristics or parameters of samples, performing the complete process or parts of the process without manual intervention. Equipment forming part of such a system is within the scope of this standard. Examples of equipment within the scope of this standard include: - analytical equipment; - automatic sampler (pipettor, aliquoter); - equipment for sample replication and amplification. NOTE 1 In the case of analytical equipment the complete process usually includes the following steps: - taking a specific quantity of the sample; - preparing the sample by chemical, thermal, mechanical or other means; - measurement; - display, transmission or printing of the results of measurement. NOTE 2 If all or part of the equipment falls within the scope of one or more other part 2 standards of IEC 61010 as well as within the scope of this standard, considerations have to be given to those other part 2 standards. 1.1.2 Equipment excluded from scope Addition: Add the following item: aa) IEC 61010-2-101 (IVD Equipment) 1.2 Object 1.2.1 Aspects included in scope Addition: Add the following items: aa) biohazards; bb) hazardous chemical substances. 1.2.2 Aspects excluded from scope Addition: Add the following item and note: aa) handling or manipulation of material outside the equipment. NOTE Requirements covering these subjects are the responsibility of committees preparing the relevant standards. --------------------------------------------------------------------------------------------------------------------------------   Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-C22.2 no 61010-2-081, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 2-081 : Exigences particulières pour les appareils de laboratoire, automatiques et semi-automatiques, destinés à l’analyse et autres usages. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-081 (deuxième édition, 2015-01) qui porte le même titre. Cette norme remplace l’édition antérieure publiée en 2004 qui portait la désignation CAN/CSA-C22.2 no 61010-2-081 (norme IEC 61010-2-081:2002 adoptée). Cette norme fait partie d’une série de normes publiées par le Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé «CAN/CSA-C22.2 no 61010-2-081». Cette norme doit être utilisée de concert avec la CAN/CSA-C22.2 no 61010-1-12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada). Cette norme est jugée convenable à l’évaluation de la conformité selon le domaine d’application établi dans la norme.   Domaine d’application et objet Cet article de la Partie 1 est applicable, à l'exception de ce qui suit: 1.1.1 Appareils inclus dans le domaine d’application Remplacement: Remplacer le texte par ce qui suit: La présente partie de l’IEC 61010 s’applique aux appareils de laboratoire, automatiques et semi-automatiques, destinés à l’analyse et autres usages. Les appareils de laboratoire automatiques et semi-automatiques comprennent les instruments ou systèmes utilisés pour mesurer ou modifier un ou plusieurs paramètres ou caractéristiques d'échantillons, réalisant tout ou partie du processus sans intervention manuelle. Les équipements faisant partie d'un tel système sont couverts par le domaine d'application de la présente norme. Exemples d'équipements entrant dans le domaine d'application de la présente norme: - équipement réalisant des analyses; - échantillonneur automatique (pipeteur, aliquoteur); - équipement réalisant la réplication ou l'amplification d'échantillon. NOTE 1 En ce qui concerne les équipements réalisant des analyses, le processus complet comprend habituellement les phases suivantes: - prélèvement d’une quantité déterminée de l’échantillon; - préparation de l’échantillon par des moyens chimiques, thermiques, mécaniques ou autres; - mesurage; - affichage, transmission ou impression des résultats de mesurage. NOTE 2 Si l'équipement dans sa totalité ou quelques-uns de ses sous-ensembles relèvent du domaine d’application d’une ou plusieurs autres Parties 2 de la norme IEC 61010 ainsi que du domaine d’application de la présente norme, ces autres Parties 2 doivent également être prises en considération. 1.1.2 Aspects exclus du domaine d’application Addition: Ajouter le point suivant: aa) IEC 61010-2-101 (appareils DIV) 1.2 Objet 1.2.1 Aspects inclus dans le domaine d’application Addition: Ajouter les points suivants: aa) dangers biologiques; bb) produits chimiques dangereux. 1.2.2 Aspects exclus du domaine d’application Addition: Ajouter le point et la note suivants: aa) la manutention ou la manipulation de substances en dehors de l'équipement. NOTE Les exigences applicables à ces sujets sont de la responsabilité des comités préparant les normes appropriées.